| Type | CZ 01 | CZ 02 |
|
|---|
| Sensing distance | 3 m | 6 m |
| Supply voltage |
12V - 25V DC |
|---|
| Output NPN, PNP | 30V
DC, 150mA
|
|---|
| Output relay | 48V, 500mA, 30W
|
|---|
| Sensitivity setting | NO |
NO |
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 63
|
|---|
| Operating temperature | -25 to +55
|
|---|
| Connecting | Cable |
|---|
| Size | 90x30x20
|
| Case |
A
|
|---|
| Type | CZ 23 | CZ 24 |
 |
|---|
| Sensing distance |
3 m | 8 m |
| Supply voltage |
12V - 25V DC |
|---|
| Output NPN, PNP |
30V DC, 150mA
|
|---|
| Output relay | 48V, 500mA, 30W
|
|---|
| Sensitivity setting | NO |
NO
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 63
|
|---|
| Operating temperature | -25 to +55
|
|---|
| Connecting | Cable/Terminal
block |
|---|
| Size | 45x30x16
|
| Case |
G |
|---|
| Type | CZ 31 |
|
|---|
| Sensing distance |
5 m
|
|---|
Accessories only for
CZ35, CZ36 |
|---|
| Pretection | IP 65
|
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting |
Cable 5m |
|---|
| Size |
10 x 31mm |
|---|
| Case |
J
|
| Type | CZ 32 |
|
|---|
| Sensing distance |
5 m |
|---|
Accessories only for
CZ35, CZ36 |
|---|
|
Protection | IP 65
|
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting |
Cable 5m |
|---|
| Size |
9x12x28 mm |
|---|
| Case |
K
|
| Type | CZ 35 |
|
|---|
| Sensing distance | 5 m
|
| Diffuse sensing distance | 0,5 m
|
|---|
| Supply voltage | 10 - 30 V
DC/AC
|
|---|
| Output NPN, PNP | 30V
DC, 0,15
|
|---|
| Output relay | 48V, 1A
|
|---|
| Sensitivity setting |
YES
|
|---|
| Time delay |
0 - 30 sec.
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 40
|
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting |
Terminal block
|
|---|
| Size |
63x23x85 |
| Case |
L
|
| Type | CZ 36 |
|
|---|
| Sensing distance | 5 m
|
| Diffuse sensing distance | 0,5 m
|
|---|
| Supply voltage | 10 - 30 V
DC/AC
|
|---|
| Output NPN, PNP | 30V
DC, 0,15A
|
|---|
| Output relay |
48V, 0,5A |
|---|
| Sensitivity setting |
YES
|
|---|
| Time delay |
0 - 30sec.
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection |
IP 40
|
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting |
Terminal block
|
|---|
| Size |
55x16x52 |
| Case |
M
|
| Type | CZ 45 | CZ 47 |
|
|---|
| Sensing distance | 5 m | 15 m
|
| Supply voltage | 12V - 25V DC
|
|---|
| Output NPN, PNP | 30V DC, 150mA
|
|---|
| Output relay | 48V, 1A, 60W
|
|---|
| Sensitivity setting | ANO | ANO
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 65 |
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting | Cable/Terminal
block
|
|---|
| Size | 80x45x30
|
| Case |
D |
|---|
| Type | CZ 53 | CZ 56 |
|
|---|
| Sensing distance | 3 m | 6 m
|
| Supply voltage | 12V - 25V DC
|
|---|
| Output NPN, PNP | 30V DC, 150mA
|
|---|
| Output relay | 48V, 500mA, 30W
|
|---|
| Sensitivity setting | NO |
NO
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 63 |
|---|
| Operating temperature |
-25 to +55
|
|---|
| Connecting | Cable |
|---|
| Size | M18x86
|
| Case |
B |
|---|
| Type | CZ 61 | CZ 62 |
|
|---|
| Diffuse senising distance | 5 m | 6 m
|
|---|
| Supply voltage |
12V - 25V DC |
|---|
| Output NPN, PNP | 30V
DC, 150mA
|
|---|
| Output relay | 48V, 0,5A, 30W
|
|---|
| Sensitivity setting |
YES | YES
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 65
|
|---|
| Operating temperature |
-25 to +55
|
| Connecting |
Cable
|
|---|
| Size | 65x58x35 |
|---|
| Type | CK 21 | CK 41 |
|
|---|
| Senising distance | 1 m | 1 m
|
|---|
| Diffuse sensing distance | 20 cm | 20 cm
|
|---|
| Supply voltage |
12 - 25V DC
|
|---|
| Output NPN, PNP | 30V
DC, 150mA
|
|---|
| Output relay | 48V, 500mA, 30W
|
|---|
| Sensitivity setting |
NO | YES
|
|---|
| Switching frequency | 90 Hz, 6ms
|
|---|
| Protection | IP 63 |
|---|
| Operating temperature | -25
to +55
|
| Connecting |
cable |
|---|
| Size | 90x30x20 80x45x30
|
|---|
| Case |
E |
|---|